Rus Articles Journal

How to reconcile the program 1C and Windows Vista

there are cases when it is not possible to start the program 1C, at the same time the dialog box 1C with the message " appears; The sorting Order established for the database differs from system! . After closing of a window the program is closed (it is possible to start it in the Configurator mode).

A cause of error and ways of elimination

the Cause of error - discrepancy of system settings and control 1C.

By the way if the operating system is localized and regional settings are established correctly, then at installation 1C of its control will be brought into accord with system.

Check of a correctness of settings

I. System settings (for the localized Russified Windows version)

1. Open Start-up - Control - the Control panel - Language and regional standards .

2. On a tab Regional parameters in the dropping-out list has to be - Russian .

3. On a tab Languages - are more detailed - the dialog box Languages and services of text input - a tab Parameters - input Language by default has to be - Russian - the Russian .

4. On a tab In addition has to be - Russian .

II. Settings 1C

1. Start the program 1C. In the Start window 1C allocate the necessary information base.

2. In the dropping-out list In the mode choose the Configurator - OK .

3. The Configurator will be started by . Choose the Administration menu - the Code page of tables IB

4. In a window the Code page of tables of information base in the dropping-out list has to be - 1251 - the Russian, Belarusian, Bulgarian and Serbian languages .

As a last resort sometimes recommend to turn off check of compliance of an order of sorting. For this purpose in the catalog of information base it is necessary to create the alarm file with the name OrdNoChk. prm (with any contents).

Notes

1. If you use to the MDIB (management of the distributed information bases) component, - at shutdown of check of an order of sorting, - it is not NECESSARY to use symbols of any alphabets, except Latin, in the trigram identifier of the information bases which are a part of the distributed base.

2. It must be kept in mind that shutdown of check of identity of an order of sorting can lead to unexpected - for the user of the program 1C! - to a sequence of lines, for example, when forming reports.

Elimination of a mistake in Windows Vista If you use

Windows Vista, then to get rid of the message The sorting order established for the database differs from system! the above-stated methods will not work well.

for this purpose:

1. Start the program 1C. In the Start window 1C allocate the necessary information base.

2. In the dropping-out list In the mode choose the Configurator - OK .

3. The Configurator will be started by . Choose the Administration menu - the Code page of tables IB

4. In a window the Code page of tables of information base in the dropping-out list choose + the Current system installation - OK .

5. In the Configurator window with the message When performing change of the code page indexes of all tables of data of information base will be reconstructed! To execute change of the code page? press Yes .

6. After the certain period depending on the IB size the Configurator window with the message " will appear; The Code page is changed! press of OK .

7. Close the Configurator , it is possible to work with information base.

8. For work with other IB change similarly the code page of tables IB.]